  3. Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

Scheduled Pinned Locked Moved Uncategorized
20 Posts 14 Posters 1 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • jamesb@fedi.duckduckpigeon.co.ukJ jamesb@fedi.duckduckpigeon.co.uk

    @revk It's not against the regulations but I'd be wary of it - mainly because I get water everywhere.

    penguin42@mastodon.org.ukP This user is from outside of this forum
    penguin42@mastodon.org.ukP This user is from outside of this forum
    penguin42@mastodon.org.uk
    wrote last edited by
    #6

    @jamesb @revk Really? I thought you weren't allowed to have sockets within touching distance?

    jamesb@fedi.duckduckpigeon.co.ukJ 1 Reply Last reply
    0
    • revk@toot.me.ukR revk@toot.me.uk

      Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

      Link Preview Image
      leonerd@fosstodon.orgL This user is from outside of this forum
      leonerd@fosstodon.orgL This user is from outside of this forum
      leonerd@fosstodon.org
      wrote last edited by
      #7

      @revk Yes I'm feeling nervous just looking at it. That said I don't think the terrible perspective on the photo composition job is helping matters

      1 Reply Last reply
      0
      • penguin42@mastodon.org.ukP penguin42@mastodon.org.uk

        @jamesb @revk Really? I thought you weren't allowed to have sockets within touching distance?

        jamesb@fedi.duckduckpigeon.co.ukJ This user is from outside of this forum
        jamesb@fedi.duckduckpigeon.co.ukJ This user is from outside of this forum
        jamesb@fedi.duckduckpigeon.co.uk
        wrote last edited by
        #8

        @penguin42 It's within 3m of zone 1 in a bathroom but there's no regulation for kitchens - only a recommendation in the building regs of 300mm. @revk

        tinmouth@infosec.exchangeT edavies@functional.cafeE 2 Replies Last reply
        0
        • revk@toot.me.ukR revk@toot.me.uk

          Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

          Link Preview Image
          urbandjent@metalhead.clubU This user is from outside of this forum
          urbandjent@metalhead.clubU This user is from outside of this forum
          urbandjent@metalhead.club
          wrote last edited by
          #9

          @revk It's horrifying! They didn't leave space to put the little pokey hole (with the plastic teeth) to hold ya tea towel 🫣🤔🤭

          1 Reply Last reply
          0
          • revk@toot.me.ukR revk@toot.me.uk

            Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

            Link Preview Image
            etchedpixels@mastodon.socialE This user is from outside of this forum
            etchedpixels@mastodon.socialE This user is from outside of this forum
            etchedpixels@mastodon.social
            wrote last edited by
            #10

            @revk Feels the same as when I saw someone with their battery and inverter next to the loo.

            Instinctively it's wrong but with modern electrical safety stuff it should be fine.

            (and likewise an outdoor rated battery install in the bog is different but even if you can't aim straight should be safe)

            davecykl@mastodon.socialD 1 Reply Last reply
            0
            • jamesb@fedi.duckduckpigeon.co.ukJ jamesb@fedi.duckduckpigeon.co.uk

              @penguin42 It's within 3m of zone 1 in a bathroom but there's no regulation for kitchens - only a recommendation in the building regs of 300mm. @revk

              tinmouth@infosec.exchangeT This user is from outside of this forum
              tinmouth@infosec.exchangeT This user is from outside of this forum
              tinmouth@infosec.exchange
              wrote last edited by
              #11

              @jamesb oh I thought it was 60cm to the side at least?

              tinmouth@infosec.exchangeT 1 Reply Last reply
              0
              • jamesb@fedi.duckduckpigeon.co.ukJ jamesb@fedi.duckduckpigeon.co.uk

                @penguin42 It's within 3m of zone 1 in a bathroom but there's no regulation for kitchens - only a recommendation in the building regs of 300mm. @revk

                edavies@functional.cafeE This user is from outside of this forum
                edavies@functional.cafeE This user is from outside of this forum
                edavies@functional.cafe
                wrote last edited by
                #12

                @jamesb @penguin42 @revk Indeed.

                However, electrical equipment also needs to be installed in accordance with the manufacturer's instructions. Some industry guidance says 300 or 600mm (I forget which) from basins so manufacturers might follow those.

                Similarly, sockets are allowed in large-enough bathrooms but the manufacturer might say not in wet rooms, whatever that means.

                penguin42@mastodon.org.ukP 1 Reply Last reply
                0
                • revk@toot.me.ukR revk@toot.me.uk

                  Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

                  Link Preview Image
                  matthewcroughan@social.defenestrate.itM This user is from outside of this forum
                  matthewcroughan@social.defenestrate.itM This user is from outside of this forum
                  matthewcroughan@social.defenestrate.it
                  wrote last edited by
                  #13
                  Of course not, it's clearly waterproof
                  1 Reply Last reply
                  0
                  • tinmouth@infosec.exchangeT tinmouth@infosec.exchange

                    @jamesb oh I thought it was 60cm to the side at least?

                    tinmouth@infosec.exchangeT This user is from outside of this forum
                    tinmouth@infosec.exchangeT This user is from outside of this forum
                    tinmouth@infosec.exchange
                    wrote last edited by
                    #14

                    @jamesb maybe I'm misremembering 2 things at once here 😂

                    1 Reply Last reply
                    0
                    • jackeric@beige.partyJ jackeric@beige.party

                      @revk also I've never seen push-toggle power switches on an extension lead, probably for good reason... and the "toggle standby power" symbol is blatantly incorrect for this. avoid avoid avoid

                      davecykl@mastodon.socialD This user is from outside of this forum
                      davecykl@mastodon.socialD This user is from outside of this forum
                      davecykl@mastodon.social
                      wrote last edited by
                      #15

                      @jackeric @revk Yeah, I also noticed the push buttons rather than rocker switches seeming very odd, and wondered whether that would actually conform to electrical regs?

                      These days •so much• random foreign-designed stuff is sold on various online tat bazaars and I suspect the safety authorities (do we even still have a suitably resourced body?) are just unable to whack-a-mole them all 😔😟

                      Then you see all the 1-star reviews: “My new charger melted and suddenly caught fire after 2 months”… 🤨😱

                      1 Reply Last reply
                      0
                      • etchedpixels@mastodon.socialE etchedpixels@mastodon.social

                        @revk Feels the same as when I saw someone with their battery and inverter next to the loo.

                        Instinctively it's wrong but with modern electrical safety stuff it should be fine.

                        (and likewise an outdoor rated battery install in the bog is different but even if you can't aim straight should be safe)

                        davecykl@mastodon.socialD This user is from outside of this forum
                        davecykl@mastodon.socialD This user is from outside of this forum
                        davecykl@mastodon.social
                        wrote last edited by
                        #16

                        @etchedpixels @revk The “aim” comment is reminding me that I remember once reading on the internet somewhere about underground/metro trains somewhere which had pictorial warning signs 🚫 on the inter-car doors of a stick man “going about his business” after a few drinks and a lightning flash indicating the perils of the live rail within “target distance”! 🚷🚱

                        1 Reply Last reply
                        0
                        • edavies@functional.cafeE edavies@functional.cafe

                          @jamesb @penguin42 @revk Indeed.

                          However, electrical equipment also needs to be installed in accordance with the manufacturer's instructions. Some industry guidance says 300 or 600mm (I forget which) from basins so manufacturers might follow those.

                          Similarly, sockets are allowed in large-enough bathrooms but the manufacturer might say not in wet rooms, whatever that means.

                          penguin42@mastodon.org.ukP This user is from outside of this forum
                          penguin42@mastodon.org.ukP This user is from outside of this forum
                          penguin42@mastodon.org.uk
                          wrote last edited by
                          #17

                          @edavies @jamesb @revk Well in that case, that one has to be installed directly behind your tap in the scariest looking location.

                          1 Reply Last reply
                          0
                          • revk@toot.me.ukR revk@toot.me.uk

                            Does that make people in the UK wince at all... A power socket right next to a tap... I know other countries seem far less worried, but wow...

                            Link Preview Image
                            rupertreynolds@hachyderm.ioR This user is from outside of this forum
                            rupertreynolds@hachyderm.ioR This user is from outside of this forum
                            rupertreynolds@hachyderm.io
                            wrote last edited by
                            #18

                            @revk One faulty piece of equipment, and those are ideal conditions to maximise injury.

                            rupertreynolds@hachyderm.ioR 1 Reply Last reply
                            0
                            • rupertreynolds@hachyderm.ioR rupertreynolds@hachyderm.io

                              @revk One faulty piece of equipment, and those are ideal conditions to maximise injury.

                              rupertreynolds@hachyderm.ioR This user is from outside of this forum
                              rupertreynolds@hachyderm.ioR This user is from outside of this forum
                              rupertreynolds@hachyderm.io
                              wrote last edited by
                              #19

                              @revk Oh, and the sockets will go gungey and the USB sockets will fail rapidly.

                              1 Reply Last reply
                              0
                              • ryanteck@fosstodon.orgR ryanteck@fosstodon.org

                                @revk It looks / feels very odd. However at the same time if I knew the property had decent electrics with RCDs / RCBOs I'm not sure I would be worried.

                                tony@toot.hoyle.me.ukT This user is from outside of this forum
                                tony@toot.hoyle.me.ukT This user is from outside of this forum
                                tony@toot.hoyle.me.uk
                                wrote last edited by
                                #20

                                @Ryanteck @revk Most people don't test their RCDs or even know they should.. It's not something I'd want a product to rely on.

                                1 Reply Last reply
                                1