Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • World
  • Users
  • Groups
Skins
  • Light
  • Brite
  • Cerulean
  • Cosmo
  • Flatly
  • Journal
  • Litera
  • Lumen
  • Lux
  • Materia
  • Minty
  • Morph
  • Pulse
  • Sandstone
  • Simplex
  • Sketchy
  • Spacelab
  • United
  • Yeti
  • Zephyr
  • Dark
  • Cyborg
  • Darkly
  • Quartz
  • Slate
  • Solar
  • Superhero
  • Vapor

  • Default (Cyborg)
  • No Skin
Collapse
Brand Logo

CIRCLE WITH A DOT

  1. Home
  2. Uncategorized
  3. Someone please explain this to me

Someone please explain this to me

Scheduled Pinned Locked Moved Uncategorized
20 Posts 11 Posters 0 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

    @funkylab haven't tried, already replaced this one (there was another 100% dead bulb in the fixture I replaced before filming this)

    funkylab@mastodon.socialF This user is from outside of this forum
    funkylab@mastodon.socialF This user is from outside of this forum
    funkylab@mastodon.social
    wrote last edited by
    #7

    @azonenberg ah cool, yeah clearly the other three bleed their offline caps nice and smoothly through the LEDs after turning off probably when detecting an undervoltage, whereas the haunted one seems to have a bad day when it comes to that… hence me wondering whether the input filtering on the other three might be causing spurs in the spookybulb's input detection.

    1 Reply Last reply
    0
    • cliffle@hachyderm.ioC cliffle@hachyderm.io

      @azonenberg I have a couple of dimmer switches that appear to not turn all the way off, presumably because they don't have neutral and must continue passing some current to satisfy their own needs. This usually manifests as one LED bulb in a fixture flickering and staying alive long past the others, though the flicker pattern I get is different.

      Is the switch a dimmer?

      azonenberg@ioc.exchangeA This user is from outside of this forum
      azonenberg@ioc.exchangeA This user is from outside of this forum
      azonenberg@ioc.exchange
      wrote last edited by
      #8

      @cliffle nope no dimmers anywhere in the house

      cliffle@hachyderm.ioC 1 Reply Last reply
      0
      • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

        Someone please explain this to me

        tezoatlipoca@mas.toT This user is from outside of this forum
        tezoatlipoca@mas.toT This user is from outside of this forum
        tezoatlipoca@mas.to
        wrote last edited by
        #9

        @azonenberg incandescent bulbs are, electrically simple. E flows from the knob to the can of the bulb stem thru the filament. Switch go off, no current, no light.

        Led bulbs have little driver boards in them that amongst other things converts 60 or 50 Hz ac into a low voltage dc. So there are capacitors in there. Some capacitors - in conjunction with a bad board design (leakage current etc) - don't discharge properly and still hold excess power for a few seconds.

        azonenberg@ioc.exchangeA 1 Reply Last reply
        0
        • lasse@social.tchncs.deL lasse@social.tchncs.de

          @azonenberg bulb is weeping because the white balance is off

          azonenberg@ioc.exchangeA This user is from outside of this forum
          azonenberg@ioc.exchangeA This user is from outside of this forum
          azonenberg@ioc.exchange
          wrote last edited by
          #10

          @lasse lol this is the only fixture in the house that takes screw base bulbs anymore so I'm just using whatever I have lying around. It's an original 1970s bathroom with a leaky shower we need to rip our and replace anyway so aesthetics of lighting are not high on my radar

          1 Reply Last reply
          0
          • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

            @cliffle nope no dimmers anywhere in the house

            cliffle@hachyderm.ioC This user is from outside of this forum
            cliffle@hachyderm.ioC This user is from outside of this forum
            cliffle@hachyderm.io
            wrote last edited by
            #11

            @azonenberg Neat. Kinda wanna put a scope on that circuit then.

            petrillic@hachyderm.ioP 1 Reply Last reply
            0
            • tezoatlipoca@mas.toT tezoatlipoca@mas.to

              @azonenberg incandescent bulbs are, electrically simple. E flows from the knob to the can of the bulb stem thru the filament. Switch go off, no current, no light.

              Led bulbs have little driver boards in them that amongst other things converts 60 or 50 Hz ac into a low voltage dc. So there are capacitors in there. Some capacitors - in conjunction with a bad board design (leakage current etc) - don't discharge properly and still hold excess power for a few seconds.

              azonenberg@ioc.exchangeA This user is from outside of this forum
              azonenberg@ioc.exchangeA This user is from outside of this forum
              azonenberg@ioc.exchange
              wrote last edited by
              #12

              @tezoatlipoca yeah but usually I see a nice smooth ramp down. Also the bulb is running when power is on... Usually.

              This one actually was dead, i only looked at it because i saw a dark spot on the fixture with no light coming from this position.

              Somehow shutting it off creates an inductive spike or something in the SMPS that makes it start running until it's drained the capacitors.

              1 Reply Last reply
              0
              • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

                Someone please explain this to me

                marshray@infosec.exchangeM This user is from outside of this forum
                marshray@infosec.exchangeM This user is from outside of this forum
                marshray@infosec.exchange
                wrote last edited by
                #13

                @azonenberg Looks like you got a diesel bulb mixed in with the rest.

                1 Reply Last reply
                0
                • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

                  Someone please explain this to me

                  johnjburnsiii@kzoo.toJ This user is from outside of this forum
                  johnjburnsiii@kzoo.toJ This user is from outside of this forum
                  johnjburnsiii@kzoo.to
                  wrote last edited by
                  #14

                  @azonenberg

                  All those electrons running around trying to stay alive... collecting together in their last refuge until they slowly & silently illum their last...

                  😎

                  1 Reply Last reply
                  0
                  • cliffle@hachyderm.ioC cliffle@hachyderm.io

                    @azonenberg Neat. Kinda wanna put a scope on that circuit then.

                    petrillic@hachyderm.ioP This user is from outside of this forum
                    petrillic@hachyderm.ioP This user is from outside of this forum
                    petrillic@hachyderm.io
                    wrote last edited by
                    #15

                    @cliffle @azonenberg now imagining a van full of hardware nerds showing up and unpacking 6 crates full of test gear to identify the problem.

                    1 Reply Last reply
                    0
                    • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

                      Someone please explain this to me

                      ldcd@social.treehouse.systemsL This user is from outside of this forum
                      ldcd@social.treehouse.systemsL This user is from outside of this forum
                      ldcd@social.treehouse.systems
                      wrote last edited by
                      #16

                      @azonenberg if they're designed to be dimmer switch compatible maybe a cap popped off or otherwise failed in the duty cycle detection circuit and it went unstable?

                      ldcd@social.treehouse.systemsL 1 Reply Last reply
                      0
                      • ldcd@social.treehouse.systemsL ldcd@social.treehouse.systems

                        @azonenberg if they're designed to be dimmer switch compatible maybe a cap popped off or otherwise failed in the duty cycle detection circuit and it went unstable?

                        ldcd@social.treehouse.systemsL This user is from outside of this forum
                        ldcd@social.treehouse.systemsL This user is from outside of this forum
                        ldcd@social.treehouse.systems
                        wrote last edited by
                        #17

                        @azonenberg I assume the way those work is by integrating the rectified voltage or something similar

                        1 Reply Last reply
                        0
                        • azonenberg@ioc.exchangeA This user is from outside of this forum
                          azonenberg@ioc.exchangeA This user is from outside of this forum
                          azonenberg@ioc.exchange
                          wrote last edited by
                          #18

                          @gme all four bulbs are in parallel and the other 3 turn off fine. It's definitely discharging stored energy in a capacitor

                          1 Reply Last reply
                          0
                          • azonenberg@ioc.exchangeA azonenberg@ioc.exchange

                            Someone please explain this to me

                            mcr314@todon.nlM This user is from outside of this forum
                            mcr314@todon.nlM This user is from outside of this forum
                            mcr314@todon.nl
                            wrote last edited by
                            #19

                            I guess that you are noticing the one bulb that stays on for awhile: @azonenberg Might be like: https://www.youtube.com/watch?v=1uEmX5XClPY the coil of wire formed a capacitor.

                            1 Reply Last reply
                            0
                            • azonenberg@ioc.exchangeA This user is from outside of this forum
                              azonenberg@ioc.exchangeA This user is from outside of this forum
                              azonenberg@ioc.exchange
                              wrote last edited by
                              #20

                              @gme the whole circuit is switched by a single 120V SPST switch controlling all four bulbs wired in parallel. There is to my knowledge no other switch.

                              And the capacitors are inside the LED bulbs as part of the SMPS circuit.

                              1 Reply Last reply
                              1
                              0
                              • R relay@relay.infosec.exchange shared this topic
                              Reply
                              • Reply as topic
                              Log in to reply
                              • Oldest to Newest
                              • Newest to Oldest
                              • Most Votes


                              • Login

                              • Login or register to search.
                              • First post
                                Last post
                              0
                              • Categories
                              • Recent
                              • Tags
                              • Popular
                              • World
                              • Users
                              • Groups