Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • World
  • Users
  • Groups
Skins
  • Light
  • Brite
  • Cerulean
  • Cosmo
  • Flatly
  • Journal
  • Litera
  • Lumen
  • Lux
  • Materia
  • Minty
  • Morph
  • Pulse
  • Sandstone
  • Simplex
  • Sketchy
  • Spacelab
  • United
  • Yeti
  • Zephyr
  • Dark
  • Cyborg
  • Darkly
  • Quartz
  • Slate
  • Solar
  • Superhero
  • Vapor

  • Default (Cyborg)
  • No Skin
Collapse
Brand Logo

CIRCLE WITH A DOT

  1. Home
  2. Uncategorized
  3. okay!

okay!

Scheduled Pinned Locked Moved Uncategorized
20 Posts 6 Posters 0 Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • whitequark@social.treehouse.systemsW whitequark@social.treehouse.systems

    it sounds really exhausting (well, really loud mainly. it is supposed to be exhausting) to be removing a maximum of 600 W of heat with a server flow-through cooler so i'm thinking about rigging up a liquid cooling setup somehow. i don't know if anybody has stock water cooling blocks for AMD SP3 socket but i think i can just do some machining and make waterblocks for it?

    malwareminigun@infosec.exchangeM This user is from outside of this forum
    malwareminigun@infosec.exchangeM This user is from outside of this forum
    malwareminigun@infosec.exchange
    wrote last edited by
    #10

    @whitequark I have a spare Heatkiller 4 sTRX4 block which should work but pretty sure shipping it to you would exceed the cost of a new one given the current... international trade clusterfuck. ( https://shop.watercool.de/HEATKILLER-IV-PRO-for-Threadripper-COPPER-NICKEL_1 )

    Most of the pre-mix coolants are water based but do have additives intended to reduce conductivity of the coolant to reduce the potential impact of leaks.

    whitequark@social.treehouse.systemsW 1 Reply Last reply
    1
    0
    • malwareminigun@infosec.exchangeM malwareminigun@infosec.exchange

      @whitequark I have a spare Heatkiller 4 sTRX4 block which should work but pretty sure shipping it to you would exceed the cost of a new one given the current... international trade clusterfuck. ( https://shop.watercool.de/HEATKILLER-IV-PRO-for-Threadripper-COPPER-NICKEL_1 )

      Most of the pre-mix coolants are water based but do have additives intended to reduce conductivity of the coolant to reduce the potential impact of leaks.

      whitequark@social.treehouse.systemsW This user is from outside of this forum
      whitequark@social.treehouse.systemsW This user is from outside of this forum
      whitequark@social.treehouse.systems
      wrote last edited by
      #11

      @malwareminigun i don't think shipping to the UK will bite (it's for personal use, no?) but i'd need two... i could buy a different (cheaper) one on aliexpress for 65 GBP each

      1 Reply Last reply
      0
      • gsuberland@chaos.socialG gsuberland@chaos.social

        @whitequark have never personally built a water cooled machine, but I have watched enough people do it to offer some general advice:

        watch out for corrosion from mixed metals.

        for a pump I recommend the D5 since it has proven to be a workhorse. running two in parallel gives redundancy and better performance with restricted flow. flow alarms are helpful, too.

        whitequark@social.treehouse.systemsW This user is from outside of this forum
        whitequark@social.treehouse.systemsW This user is from outside of this forum
        whitequark@social.treehouse.systems
        wrote last edited by
        #12

        @gsuberland bykski d5?

        gsuberland@chaos.socialG 1 Reply Last reply
        0
        • gsuberland@chaos.socialG gsuberland@chaos.social

          @whitequark have never personally built a water cooled machine, but I have watched enough people do it to offer some general advice:

          watch out for corrosion from mixed metals.

          for a pump I recommend the D5 since it has proven to be a workhorse. running two in parallel gives redundancy and better performance with restricted flow. flow alarms are helpful, too.

          gsuberland@chaos.socialG This user is from outside of this forum
          gsuberland@chaos.socialG This user is from outside of this forum
          gsuberland@chaos.social
          wrote last edited by
          #13

          @whitequark fluid wise I don't know if glycol will end up being too viscous to flow well, especially through skived microfins in water blocks.

          most people just go with water plus a corrosion inhibitor + biocide additive and hope for the best.

          whitequark@social.treehouse.systemsW 1 Reply Last reply
          0
          • gsuberland@chaos.socialG gsuberland@chaos.social

            @whitequark fluid wise I don't know if glycol will end up being too viscous to flow well, especially through skived microfins in water blocks.

            most people just go with water plus a corrosion inhibitor + biocide additive and hope for the best.

            whitequark@social.treehouse.systemsW This user is from outside of this forum
            whitequark@social.treehouse.systemsW This user is from outside of this forum
            whitequark@social.treehouse.systems
            wrote last edited by
            #14

            @gsuberland could always fill it with galden haha

            gsuberland@chaos.socialG 1 Reply Last reply
            0
            • whitequark@social.treehouse.systemsW whitequark@social.treehouse.systems

              @gsuberland bykski d5?

              gsuberland@chaos.socialG This user is from outside of this forum
              gsuberland@chaos.socialG This user is from outside of this forum
              gsuberland@chaos.social
              wrote last edited by
              #15

              @whitequark the pump itself is a D5, there are tons of different manufacturers selling pump units that integrate them.

              whitequark@social.treehouse.systemsW 1 Reply Last reply
              0
              • gsuberland@chaos.socialG gsuberland@chaos.social

                @whitequark the pump itself is a D5, there are tons of different manufacturers selling pump units that integrate them.

                whitequark@social.treehouse.systemsW This user is from outside of this forum
                whitequark@social.treehouse.systemsW This user is from outside of this forum
                whitequark@social.treehouse.systems
                wrote last edited by
                #16

                @gsuberland what... does D5 mean here? model number? size?

                gsuberland@chaos.socialG 1 Reply Last reply
                0
                • whitequark@social.treehouse.systemsW whitequark@social.treehouse.systems

                  @gsuberland could always fill it with galden haha

                  gsuberland@chaos.socialG This user is from outside of this forum
                  gsuberland@chaos.socialG This user is from outside of this forum
                  gsuberland@chaos.social
                  wrote last edited by
                  #17

                  @whitequark if you use distilled water and an additive it's at least not gonna instakill your board if there's a minor leak tbf

                  I've seen builders get away with absolutely soaking boards and then just waiting for them to dry and carrying on.

                  main thing is just making sure you have no slow leaks that will cause problems unattended.

                  whitequark@social.treehouse.systemsW 1 Reply Last reply
                  0
                  • gsuberland@chaos.socialG gsuberland@chaos.social

                    @whitequark if you use distilled water and an additive it's at least not gonna instakill your board if there's a minor leak tbf

                    I've seen builders get away with absolutely soaking boards and then just waiting for them to dry and carrying on.

                    main thing is just making sure you have no slow leaks that will cause problems unattended.

                    whitequark@social.treehouse.systemsW This user is from outside of this forum
                    whitequark@social.treehouse.systemsW This user is from outside of this forum
                    whitequark@social.treehouse.systems
                    wrote last edited by
                    #18

                    @gsuberland hm yeah you're right, i could verify the conductivity of the water to be in Gohm range and then it's likely fine; plus I'm not aiming for aesthetics so i could teflon tape the everliving hell of every connection

                    azonenberg@ioc.exchangeA 1 Reply Last reply
                    0
                    • whitequark@social.treehouse.systemsW whitequark@social.treehouse.systems

                      @gsuberland what... does D5 mean here? model number? size?

                      gsuberland@chaos.socialG This user is from outside of this forum
                      gsuberland@chaos.socialG This user is from outside of this forum
                      gsuberland@chaos.social
                      wrote last edited by
                      #19

                      @whitequark it's the short name for the actual pump component used inside the thing.

                      what you buy is the pump in a housing with the right fittings for watercooling and an adapter for some standard pc power connector. lots of companies sell them, it's sorta like system integrators but for pumps I guess

                      1 Reply Last reply
                      0
                      • whitequark@social.treehouse.systemsW whitequark@social.treehouse.systems

                        @gsuberland hm yeah you're right, i could verify the conductivity of the water to be in Gohm range and then it's likely fine; plus I'm not aiming for aesthetics so i could teflon tape the everliving hell of every connection

                        azonenberg@ioc.exchangeA This user is from outside of this forum
                        azonenberg@ioc.exchangeA This user is from outside of this forum
                        azonenberg@ioc.exchange
                        wrote last edited by
                        #20

                        @whitequark @gsuberland well conductivity of the water is part of the issue but also pcb cleanliness. If it's covered in domestic dust full of salty skin flakes etc then DI water leaks will still result in conductive runoff