<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0"><channel><title><![CDATA[Post fan&#x2F;GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part.]]></title><description><![CDATA[<p>Post fan/GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part. CPU VRM temperatures during a big compile job are less than the *idle* temps previously.</p><p>But I'm now seeing NIC temperature and it's concerningly hot. I'm not sure why it wasn't showing up before so I have no idea how toasty it was.</p><p>I'm also seeing what appears to be poor / unstable network performance.</p><p>The ConnectX6 is passively air cooled and sits just to the right of the new 80mm fans (as seen from the rear panel), and I suspect what is happening is that the negative pressure from the new fans is drawing front-to-back airflow slightly to the left and reducing airflow over its heatsink. Thermal engineering is hard.</p><p>I have another PCIe slot exhaust fan on order coming tomorrow so hopefully things are tolerable between now and then.</p>

<div class="row mt-3"><div class="col-12 mt-3"><img class="img-thumbnail" src="https://files.ioc.exchange/iocexchange/media_attachments/files/116/573/136/239/285/418/original/2031ab861f941434.png" alt="Link Preview Image" /></div></div>]]></description><link>https://board.circlewithadot.net/topic/e068d2e0-1062-46f9-b03a-1b1481176f58/post-fan-gpu-upgrade-and-some-additional-fan-rpm-tuning-via-ipmi-vm-server-is-running-a-lot-cooler-for-the-most-part.</link><generator>RSS for Node</generator><lastBuildDate>Fri, 15 May 2026 05:19:43 GMT</lastBuildDate><atom:link href="https://board.circlewithadot.net/topic/e068d2e0-1062-46f9-b03a-1b1481176f58.rss" rel="self" type="application/rss+xml"/><pubDate>Thu, 14 May 2026 13:28:03 GMT</pubDate><ttl>60</ttl><item><title><![CDATA[Reply to Post fan&#x2F;GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part. on Thu, 14 May 2026 16:21:04 GMT]]></title><description><![CDATA[<p>We can also see the bad network performance in the CPU usage charts, showing up as increased dom0 iowait time due to CephFS operations lagging</p>

<div class="row mt-3"><div class="col-12 mt-3"><img class="img-thumbnail" src="https://files.ioc.exchange/iocexchange/media_attachments/files/116/573/840/657/123/244/original/d6c7e15dced227b8.png" alt="Link Preview Image" /></div></div>]]></description><link>https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573841975689880</link><guid isPermaLink="true">https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573841975689880</guid><dc:creator><![CDATA[azonenberg@ioc.exchange]]></dc:creator><pubDate>Thu, 14 May 2026 16:21:04 GMT</pubDate></item><item><title><![CDATA[Reply to Post fan&#x2F;GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part. on Thu, 14 May 2026 16:19:04 GMT]]></title><description><![CDATA[<p>The SSD is slightly cooler, other than a short spike right after boot that might be  before the fans spun up fully or something</p>

<div class="row mt-3"><div class="col-12 mt-3"><img class="img-thumbnail" src="https://files.ioc.exchange/iocexchange/media_attachments/files/116/573/831/881/624/618/original/e7223b72c79dbfbf.png" alt="Link Preview Image" /></div></div>]]></description><link>https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573834064936603</link><guid isPermaLink="true">https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573834064936603</guid><dc:creator><![CDATA[azonenberg@ioc.exchange]]></dc:creator><pubDate>Thu, 14 May 2026 16:19:04 GMT</pubDate></item><item><title><![CDATA[Reply to Post fan&#x2F;GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part. on Thu, 14 May 2026 16:17:15 GMT]]></title><description><![CDATA[<p>Historical network traffic before and after the recent reconfiguration.</p><p>I wonder why all my virtual desktops are so slow?</p>

<div class="row mt-3"><div class="col-12 mt-3"><img class="img-thumbnail" src="https://files.ioc.exchange/iocexchange/media_attachments/files/116/573/823/788/393/699/original/9f908f369c17bf1a.png" alt="Link Preview Image" /></div></div>]]></description><link>https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573826965981349</link><guid isPermaLink="true">https://board.circlewithadot.net/post/https://ioc.exchange/users/azonenberg/statuses/116573826965981349</guid><dc:creator><![CDATA[azonenberg@ioc.exchange]]></dc:creator><pubDate>Thu, 14 May 2026 16:17:15 GMT</pubDate></item><item><title><![CDATA[Reply to Post fan&#x2F;GPU upgrade, and some additional fan RPM tuning via IPMI: VM server is running a lot cooler, for the most part. on Thu, 14 May 2026 13:57:41 GMT]]></title><description><![CDATA[<p><span><a href="/user/azonenberg%40ioc.exchange">@<span>azonenberg</span></a></span> I recently upgraded the firmware on twelve ConnectX-6 Dx cards, took something like 5 minutes per card (including one reboot), that 5 minutes was enough to make the heatsink too hot to touch. This was on a box with decent airflow too</p>]]></description><link>https://board.circlewithadot.net/post/https://mastodon.online/users/karppinen/statuses/116573278171020043</link><guid isPermaLink="true">https://board.circlewithadot.net/post/https://mastodon.online/users/karppinen/statuses/116573278171020043</guid><dc:creator><![CDATA[karppinen@mastodon.online]]></dc:creator><pubDate>Thu, 14 May 2026 13:57:41 GMT</pubDate></item></channel></rss>